Self-Priming Pump Technology

Self-priming wastewater pumps solve the fundamental challenge of centrifugal pump operation in suction lift applications by automatically evacuating air from both the pump casing and suction piping. Unlike standard centrifugal pumps that require flooded suction conditions, self-priming pumps can start dry and establish their own prime, making them essential for above-ground installations.

These pumps combine the efficiency and reliability of centrifugal pump technology with specialized priming chambers and internal recirculation systems that enable operation with suction lifts up to 25 feet. This capability makes them ideal for pump stations where the pump must be located above the wet well, emergency applications, and portable pumping systems.

Self-Priming Advantages

Automatic Operation

No manual priming required - pumps start automatically when called upon by control systems.

Suction Lift Capability

Handle suction lifts up to 25 feet, enabling flexible pump station design.

Easy Maintenance

Above-ground installation provides full access for inspection and service.

High Efficiency

Centrifugal pump efficiency once primed, typically 70-85% at design point.

Priming System Technology

Volute Priming Chamber

Enhanced volute design with integral priming chamber that retains liquid after shutdown to enable rapid repriming on restart.

Design Features:

  • Enlarged volute chamber
  • Internal liquid retention baffle
  • Air separation and venting
  • Recirculation passages
  • Check valve integration

Operating Principle:

  • Retained liquid creates initial seal
  • Impeller action creates vacuum
  • Air is evacuated through priming chamber
  • Liquid column is established
  • Normal pumping operation begins

External Priming Tank

Separate priming reservoir maintains liquid supply for pump priming, ensuring reliable operation even after extended shutdown periods.

Components:

  • Dedicated priming tank
  • Priming liquid supply line
  • Level sensing and controls
  • Automatic refill system
  • Air release valving

Advantages:

  • Guaranteed priming liquid availability
  • Faster priming cycles
  • Suitable for frequent starts
  • Independent of pump design
  • Retrofit capability

Vacuum-Assisted Priming

Mechanical vacuum pump or ejector system actively removes air from the pump and suction piping for rapid, reliable priming.

System Types:

  • Mechanical vacuum pumps
  • Liquid ring vacuum pumps
  • Steam ejectors
  • Water jet ejectors
  • Air-operated ejectors

Applications:

  • Large suction lift requirements
  • Long suction lines
  • Critical applications
  • Multiple pump systems
  • High-speed priming needs

Technical Specifications

Performance Range

Flow Rates 50-1,500 GPM
Municipal: 200-1,000 GPM typical
Head Capacity Up to 120 feet total head
Typical range: 25-80 feet
Suction Lift Up to 25 feet vertical lift
Typical: 10-20 feet practical
Priming Time 2-10 minutes typical
Depends on suction line volume

Design Parameters

Solids Handling 1-3 inches spherical solids
Varies by impeller design
Motor Sizes 5-150 HP
Three-phase standard
Efficiency 70-85% at design point
Decreases at part load
Temperature Range 32-140°F standard
Higher temps available

Construction Materials

Pump Casing Cast iron or ductile iron
Stainless steel available
Impeller Cast iron, bronze, or SS
Open, semi-open, or closed
Shaft 416 or 17-4 PH stainless steel
Oversized for reliability
Mechanical Seal Silicon carbide faces
Cartridge design preferred

Primary Applications

Municipal Lift Stations

Above-ground pump installations where the pump must be located higher than the wet well for maintenance access or flood protection.

Design Advantages:

  • Pump room above flood level
  • Easy maintenance access
  • Better security and protection
  • Reduced excavation costs
  • Improved operator safety

Typical Configurations:

  • Duplex or triplex installations
  • Variable speed drives
  • Remote monitoring systems
  • Emergency backup pumps
  • Redundant priming systems

Industrial Process Water

Manufacturing facilities requiring reliable pumping of process wastewater, cooling water, and industrial fluids from collection sumps.

Industrial Benefits:

  • Handles temperature variations
  • Chemical compatibility options
  • Process integration capability
  • Automatic operation
  • Reduced maintenance downtime

Common Applications:

  • Cooling tower blowdown
  • Process wastewater transfer
  • Storm water management
  • Chemical transfer systems
  • Emergency spill response

Emergency & Portable Systems

Temporary and emergency pumping applications where quick deployment and automatic operation are essential for flood control and bypass pumping.

Emergency Features:

  • Rapid deployment capability
  • Trailer-mounted configurations
  • Diesel engine drive options
  • Automatic start/stop controls
  • Weather-resistant construction

Applications:

  • Flood emergency pumping
  • Construction dewatering
  • Bypass pumping during repairs
  • Disaster response operations
  • Temporary transfer systems

Commercial Buildings

Large commercial and institutional facilities requiring reliable wastewater pumping from basement levels or below-grade areas.

Building Applications:

  • Basement sewage ejection
  • Parking garage drainage
  • Kitchen grease trap pumping
  • Laundry wastewater transfer
  • Foundation drainage systems

Design Considerations:

  • Sound attenuation requirements
  • Space constraints
  • Building code compliance
  • Maintenance accessibility
  • Backup power integration

System Design Considerations

Suction System Design

  • Suction Piping: Minimize length and elevation changes
  • Pipe Sizing: Lower velocities reduce friction losses
  • Air Elimination: Avoid high points that trap air
  • Foot Valve: Required to maintain prime during shutdown
  • Strainer: Protect pump from large debris
  • Submergence: Adequate to prevent vortexing

NPSH Requirements

  • NPSH Available: Account for suction lift and losses
  • NPSH Required: Pump characteristic from manufacturer
  • Safety Margin: Minimum 3-5 feet above required
  • Temperature Effects: Higher temps reduce NPSH available
  • Altitude Correction: Higher elevations reduce atmospheric pressure
  • Vapor Pressure: Consider fluid properties

Priming System Sizing

  • Air Volume: Calculate total air in pump and piping
  • Priming Time: Balance speed vs. energy consumption
  • Liquid Requirements: Size priming tank appropriately
  • Vacuum Capacity: Match to system air leakage
  • Control Logic: Automatic vs. manual priming cycles
  • Backup Systems: Redundancy for critical applications

Installation Requirements

  • Foundation: Rigid mounting to minimize vibration
  • Alignment: Pump and motor centerlines
  • Piping Support: Independent of pump casing
  • Electrical: Motor starters and controls
  • Ventilation: Motor cooling and room air exchange
  • Drainage: Floor drains for maintenance spills

Operation & Maintenance

Startup Procedures

1

Pre-Start Inspection

  • Check priming liquid level
  • Verify suction valve is open
  • Confirm discharge valve position
  • Inspect for leaks or damage
2

Priming Cycle

  • Start priming system if equipped
  • Fill pump casing with liquid
  • Vent air from high points
  • Verify prime establishment
3

Pump Start

  • Start pump motor
  • Gradually open discharge valve
  • Monitor pressure and flow
  • Check for proper operation

Routine Maintenance

Daily Checks:

  • Visual inspection for leaks
  • Monitor pressure gauges
  • Check unusual noise or vibration
  • Verify control system operation

Weekly Maintenance:

  • Check priming system operation
  • Inspect suction strainer
  • Verify foot valve function
  • Test alarm systems

Monthly Service:

  • Check coupling alignment
  • Inspect mechanical seal
  • Verify motor bearing lubrication
  • Test priming cycle timing

Annual Overhaul:

  • Replace mechanical seals
  • Inspect impeller condition
  • Check bearing replacement
  • Calibrate control systems

Troubleshooting Guide

Priming Problems

Pump Won't Prime

  • Check priming liquid supply
  • Verify foot valve sealing
  • Inspect suction line for air leaks
  • Confirm adequate submergence
  • Check for blocked suction strainer

Loses Prime During Operation

  • Inspect mechanical seal leakage
  • Check suction piping joints
  • Verify foot valve condition
  • Confirm NPSH availability
  • Check for cavitation damage

Performance Issues

Low Flow or Pressure

  • Check impeller for wear or damage
  • Verify pump rotation direction
  • Inspect for partial blockages
  • Check system head calculations
  • Verify motor speed and voltage

Excessive Vibration

  • Check pump-motor alignment
  • Inspect impeller balance
  • Verify foundation integrity
  • Check bearing condition
  • Confirm proper piping support

Reliable Self-Priming Pump Solutions